APPLICATION

The intrinsically safe or general purpose point level switch package provides high or low liquid level detection with one relay or reed switch output, and a compact junction box for wiring termination. Available in three level sensor technologies, choose the sensor type based upon your application media and classification. Select ultrasonic for chemicals and light weight oils; vibration for wastewater with light coating or scaling; and buoyancy for clean water and non-coating chemicals. This PP or PVDF level switch package is selected for bulk storage, IBC or drum, and neutralization tank applications, connected to a PLC or relay controller.

FEATURES

  • Rugged PP or PVDF construction for use with corrosive liquids
  • Available in intrinsically safe and general purpose classifications
  • 60VA relay or 15VA dry contact switches selectable NO or NC via wiring
  • Offered in three sensing technologies for broad application coverage
  • PP enclosure rated NEMA 4X with swivel base for conduit alignment

PRICING

P/N Description From
AX1X with LU10 AU18-4243-A IS ultrasonic level switch with junction box, 1 relay, PP, 2″ NPT $695.00
AU18-4247-A IS ultrasonic level switch with junction box, 1 relay, PP, 1 1/2″ G $725.00
AU18-5243-A IS ultrasonic level switch with junction box, 1 relay, PVDF, 2″ NPT $910.00
AU18-5247-A IS ultrasonic level switch with junction box, 1 relay, PVDF, 1 1/2″ G $965.00
AX1X with LV10 AV16-4243-A GP buoyancy level switch with junction box, 1 reed, PP, 2″ NPT $520.00
AV16-4247-A GP buoyancy level switch with junction box, 1 reed, PP, 1 1/2″ G $530.00
AV16-5243-A GP buoyancy level switch with junction box, 1 reed, PVDF, 2″ NPT $735.00
AV16-5247-A GP buoyancy level switch with junction box, 1 reed, PVDF, 1 1/2″ G $745.00
AX1X with LZ12 AZ18-4243-A GP vibration level switch with junction box, 1 relay, PP, 2″ NPT $735.00
AZ18-4247-A GP vibration level switch with junction box, 1 relay, PVDF, 1 1/2″ G $765.00

COMPATIBLE ACCESSORIES

Indicators & Controllers
P/N Description From
LC40-1001 GP level switch controller LC40-1001 GP level switch controller, 120/240 VAC, 10A relay, PP $285.00
LC92-1001 IS level switch controller, 120/240 VAC, 10A relay, PP $610.00
LM92 Single NEMA box LM92-1202 Single NEMA box, 35mm rail, windowed, PC $520.00
LM92 Double NEMA box LM92-2202 Double NEMA box, 35mm rail, windowed, PC $552.00
LC95-2001 Power supply LC95-2001 Power supply, 100-240 VAC, 24 VDC @ 0.45A $335.00

DOCUMENTATION

Length: 6” to 10’ (15cm to 3m)

Accuracy: ± 1mm in water

Repeatability: ± 0.5mm in water

Orientation: ± 20º vertical

Switch points: 1 (factory set)

Supply voltage: AV16: N/A, AU18: 12-36 VDC, AZ18: 12-30 VDC

Consumption: AV16: N/A, AU18 / AZ18: 25 mA maximum

Contact type: AV16: (1) SPDT reed, AU18 / AZ18: (1) SPST relay

Contact rating: AV16: 15 VA, 0.25A max., AU18 / AZ18: 60 VA, 1A max.

Contact output: Selectable NO / NC

Process temp.: F: -40° to 176°, C: -40° to 80°

Ambient temp.: F: -40° to 140°, C: -40° to 60°

Installed height: 3.6” (9.1cm) above tank process mount

Pressure: AV16: 25 psi (1.7 bar), AU18 / AZ18: 150 psi (10 bar)

Enclosure rating: NEMA 4X (IP65)

Enclosure mat.: PP, UL94VO

Terminal strip: 6-pole, socket

Conduit entrance: 1/2” NPT

Wetted material: AV16-224X: PP, AU18-224X: PP, AU18-524X: PVDF, AZ18-424X: PP-Ryton®

Process mount: -X243: 2” NPT, -X247: 1-1/2” G

Classification: AV16 / AZ18: general purpose, AU18: intrinsically safe (see LU10 data sheet for details)

Compliance: CE