APPLICATION
The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for petroleum, water, wastewater and diluted chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with diluted or non-corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a tank adapter, flange fitting or metal stand-pipe. Typical applications include bulk storage, tanker truck, process tank, waste sump and neutralization tanks.
FEATURES
- Rugged 316L stainless steel antenna and process mount
- Simple configuration via integral push button display module
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- Rugged IP67 aluminum enclosure with polycarbonate window
PRICING
P/N | Description | From |
---|---|---|
LR15-0010-20 | 1-1/2″ NPT, 2″ (48mm) horn, 316L | $2,400.00 |
LR15-0010-30 | 1-1/2″ NPT, 3″ (78mm) horn, 316L | $2,500.00 |
LR15-0010-40 | 1-1/2″ NPT, 4″ (98mm) horn, 316L | $2,600.00 |
SENSOR TECHNOLOGIES
Select ultrasonic for chemicals and light weight oils; vibration for wastewater with light coating or scaling; buoyancy for clean water and non-coating chemicals.
DOCUMENTATION
SPECIFICATIONS
Range: 12” to 98.4’ (30cm to 30m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: – 20: 18º, – 30: 12º, – 40: 8º
Configuration: Push button
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 16-26 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -76º to 302º, C: -60º to 150º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 150 psi (-1 to 10 bar)
Enclosure rating: IP67
Encl. material: Aluminum w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug
Antenna material: 316L
Process mount: 1 1/2” NPT
Classification: General purpose
Certification: cTUVus, FCC
Compliance: CE, CRN, RoHS
PRODUCT SELECTION
If you want help in selecting a sensor for your application, please submit a Level Questionnaire. An engineer will review your requirements and suggest a product solution via email.