Bulk Storage

Level Transmitters

Series LR20 LR10 LR15 LU80-84 LU23-29
Technology Pulse radar Pulse radar Pulse radar Ultrasonic Ultrasonic
Classification General purpose General purpose General purpose General purpose General purpose
Tank location and material Above or below grade in any tank material Above grade metal or below grade in any tank material Above or below grade in any tank material Above or below grade in any tank material Above or below grade in any tank material
Corrosive Yes Yes Diluted Yes Yes
Foam Yes Minimal Yes No No
Vapor Yes Yes Yes No No
Condensation Yes Minimal Yes Minimal Minimal
Max. range 65.6′ (20m) 32.8′ (10m) 98.4′ (30m) 32.8′ (10m) 32.8′ (10m)
Max. temperature 302 F. (150°C.) 176° F. (80° C.) 302° F. (150° C.) 140° F. (60° C.) 140° F. (60° C.)
Max. pressure 72 PSI (5 bar) 43.5 PSI (3 bar) 150 PSI (10 bar) 30 PSI (2 bar) 30 PSI (2 bar)
Installation Flange Tank adapter or flange Tank adapter or flange Tank adapter or flange Tank adapter or flange
Mount 3″, 4″ ANSI 1 1/2″ NPT 1 1/2″ NPT 1″, 2″ NPT (G) 1″, 2″ NPT (G)
Configuration Push button Push button Push button Push button WebCal
Probe material 316L & PTFE PTFE 316L PVDF PVDF

Accessories

Contact Us