What's New
Level Innovation

Description Specification
The general purpose, ultrasonic sensor provides non-contact level detection up to 98.4" (2.5m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for day tanks, sumps, IBC totes, lift stations and mini-bulk storage applications.
Range:
4" to 8.2' (2.5m)
Signal output:
4-20 mA, two-wire
Contact type:
(4) SPST relays 1A
Enclosure rating:
Type 6P
Process mount:
1" NPT (1" G)

Description Specification
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays and a two-wire 4-20 mA level measurement output. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. EchoPod is broadly selected for small atmospheric day tank, skid or process vessel, lift station, IBC, drum and sump applications.
Range:
2" to 49.2" (1.25m)
Signal output:
4-20 mA, two-wire
Contact type:
(4) SPST relays 1A
Enclosure rating:
Type 6P
Process mount:
1" NPT (1" G)

Description Specification
The general purpose, ultrasonic sensor provides non-contact level detection up to 49.2" (1.25m) with 4 SPST 60 VA 1A relays. The DS14 directly replaces contact switches connected to a PLC with 1-4 discrete points for easy design conversion or field retrofit. Each relay can be configured on a single set point alarm or latched on two sets for automatic fill or empty in simplex or duplex control modes with fail-safe logic. The embedded controller can replace external control hardware. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DS14 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel, lift station and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool.
Range:
2" to 49.2" (1.25m)
Signal output:
None
Contact type:
(4) SPST relays 1A
Enclosure rating:
Type 6P
Process mount:
1" NPT (1" G)

Description Specification
The general purpose, DX10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 0-5 VDC, 0-10 VDC or 976-2000 Hz. frequency output. Select the voltage output to directly replace a contact measurement sensor connected to a PLC analog input. Select the frequency output to replace a contact measurement sensor or switch assembly, and eliminate the cost of an analog input card by connecting the DX10 to a PLC discrete input. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DX10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool.
Range:
2" to 49.2" (1.25m)
Signal output:
0-5 V, 0-10 V, 976-2000 Hz
Contact type:
None
Enclosure rating:
Type 6P
Process mount:
1" NPT (1" G)

Description Specification
The general purpose, DL10 ultrasonic sensor provides non-contact level measurement up to 49.2" (1.25m) with a 4-20 mA output. The DL10 directly replaces contact measurement sensors connected to a PLC analog input card for easy design conversion or field retrofit. The two-wire, 4-20 mA output is ideal for longer signal distances up to 1000'. The sensor is well suited for a wide range of corrosive, sticky or dirty type media. The DL10 is broadly selected for small atmospheric tank, IBC, drum, skid or process vessel and sump applications. To configure EchoPod, download our free WebCal software and purchase one USB interface tool.
Range:
2" to 49.2" (1.25m)
Signal output:
4-20 mA, two-wire
Contact type:
None
Enclosure rating:
Type 6P
Process mount:
1" NPT (1" G)

Description Specification
WebCal software makes level measurement, switch and control configuration fast and easy. Take control of your level process with WebCal's intuitive interface, pre-programmed menus, tank set point graphics and custom wiring diagrams. To configure your WebCal enabled sensor, simply download your free copy of WebCal, create or open a saved configuration file, and click Write to Unit. Its that simple.

OS required:
Windows® XP & 2000
HD space required:
10 MB
RAM required:
256 MB
Ports required:
(1) USB® 2.0

Description Specification
FM approved explosion proof for use in hazardous applications, the two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' or 10 m, and is well suited for challenging corrosive, slurry or waste liquids. Push button calibrated, the transmitter is typically selected for atmospheric bulk storage, day tank and waste sump applications located within a classified area. Media examples include sodium hypochlorite, diesel fuel and paint. The integral display and push button module enable fast and simple calibration.
Range:
8" to 32.8' (20cm to 10m)
Signal output:
4-20 mA, two-wire
Enclosure rating:
NEMA 4
Process mount:
2" NPT
Description Specification
CSA approved explosion proof for use in hazardous applications, the loop powered field meter displays engineering units connected in series with one 4-20 mA transmitter. The meter is typically selected for use with an explosion proof transmitter within a hazardous area. The windowed field enclosure is wall mounted for convenient viewing.
Display type:
LCD, 5 1/2 digit
Sensor input:
(1) 4-20 mA input
Contact type:
None
Enclosure mount:
Field
Description Specification
The general purpose two-wire pressure transmitter is offered in two termination packages and provides contact level measurement up to 69' or 21.1m of water column. Select the -S_01 for cable termination or the -S_11 for conduit termination with an integral junction box. The transmitter is best applied with clean liquid or gas media including water, oil and air. Application examples include irrigation equipment, pumping systems and compressors.
Range:
0 psi (0 bar) - 30 psi (2 bar)
Signal output:
4-20 mA, two-wire
Enclosure rating:
IP65
Cable length:
9' (3 m)
Description Specification
The general purpose two-wire pressure transmitter is offered in two configurations for different liquid types and provides contact level measurement up to 46' or 14m of water column. Select the LD31 for clean or relatively clean water, light weight oils and diluted chemical media. Application examples include ground water, ponds and wells. Select the LD32 for dirty, sludge or slurry media. Application examples include sewer or storm pump lift stations, storage and treatment with surface foam or debris where ultrasonic cannot be applied.
Range:
0 psi (0 bar) - 20 psi (1.38 bar)
Signal output:
4-20 mA, two-wire
Enclosure rating:
IP67
Cable length:
40' (12.2 m) or 60' (18.3 m)
DataSwitch Remote Relay Controller
Description Specification
The general purpose controller has a graphic display with four 4-20 mA transmitter input channels and 6 programmable relays. Select from one of three run mode configurations including 1) Multi-tank with 4 inputs and 4 relays; or 2) Pump control with 1 input and 6 relays for lift stations including duplexing; or 3) Differential level with 2 inputs and 4 relays for municipal screen or rake control. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control. The LCD displays engineering units, relay and span status for each channel. The MicroSD card is ideal for data-logging storage and retrieval.
Display:
Backlit LCD
Input channel:
(1) 4-20 mA
Contact type:
(6) mechanical contact relays
Enclosure mount:
35 mm DIN rail
Description Specification
The general purpose ultrasonic switch and controller provides non-contact level detection up to 24.6' (7.5 m) with 3 SPDT 60 VA 1A relays. EchoSwitch II features an LCD display with digital push button configuration. Each relay can be configured on a single set point alarm or latched on two set points for automatic fill or empty in simplex, duplex or triplex control modes with integral timer delay. The switch is well suited for a broad range of corrosive, waste and slurry type media. EchoSwitch II is broadly selected for atmospheric day tank, pump lift station and sump applications.
Range:
4" to 24.6' (10cm to 7.5m)
Configuration:
Push button (no target required)
Contact type:
(3) SPDT relays
Process mount:
2" NPT (2" G)

Description Specification
The general purpose two-wire ultrasonic transmitter provides non-contact level measurement up to 32.8' (10 m), and is well suited for challenging ultrapure, corrosive, slurry or waste liquids. The transmitter is broadly selected for atmospheric bulk storage, day tank, waste sump, process vessel, IBC tote, 55-gallon drum and waste sump applications. Media examples include acetic acid and resin.
Range:
4" to 32.8' (10cm to 10m)
Signal output:
4-20 mA, two-wire
Enclosure rating:
Type 6P
Process mount:
1" / 2" NPT (1" / 2" G)
Description Specification
Offered in intrinsically safe and general purpose configurations, the loop powered panel meter displays engineering units connected in series with one 4-20 mA transmitter. Select the LI25-2001 meter for hazardous applications with an intrinsically safe level transmitter. Select the LI25-1001 meter for general purpose applications. For field mount installations, order the single or two meter NEMA box.
Display type:
LCD, 5 digit
Sensor input:
(1) 4-20 mA input
Contact type:
None
Enclosure mount:
1/8 DIN, panel mount
Description Specification
The general purpose meter displays engineering units with one 4-20 mA or 0-10 VDC transmitter input channel and is offered in three configurations with optional 2 or 4 relays, 4 or 8 set points and an isolated 4-20 mA repeater. Each relay can be configured on a single set point or latched on two set points for automatic fill or empty control including duplexing. For field mount installations, order the single or two meter NEMA box.
Display type:
LED, 6 digit
Sensor input:
(1) 4-20 mA input
Contact type:
(4) 3A SPDT relays
Enclosure mount:
1/8 DIN, panel mount


Home | Search | Introduction | About Flowline | What's New | Solutions Wheel | Contact Flowline
Selection Guide | Application Guide | Browse the Products | Request Catalog | New Products
My Distributor | FAQs | Tech-Tips | Case Studies | Flowline News
Glossary | Success Stories | Technical | Chemical
Request Quote | Registration | White Papers

The Flowline Liquid Intelligence and Digital Infinity logo's are all trademarks and/or service marks of Flowline. No trademark or service mark license is granted in connection with the materials contained in the Flowline web site. This web site and all of the information it contains are provided as is without warranty of any kind, whether expressed or implied. All implied warranties, including, without limitation, implied warranties of merchantability, fitness for a particular purpose, and non-infringement, are hereby expressly disclaimed. No reproduction or republication without the prior written permission of Flowline. Specifications subject to change without notice.

©1999-2009 Flowline Liquid Intelligence
10500 Humbolt Street, Los Alamitos, CA 90720 USA
Phone: (562) 598-3015 • Fax: (562) 431-8507 • Email: levelsolutions@flowline.com