Caustic Soda Bulk Tank Level Measurement

Sodium hydroxide is commonly applied in industrial and municipal wastewater treatment applications. The challenge with caustic is that it crystallizes and ultimately coats contact type level sensors. Such coating impacts sensor performance. Flowline ultrasonic transmitters are the non-contact level measurement solution for caustic tank inventory monitoring applications. It's level made simple!

The LU14 (3" minimum beam width) is installed in a flange fitting located 6" from the side wall of a 25' tank. The LI12 panel meter provides tank level indication and control.
LU14 Ultrasonic Level
Transmitter with 0-32’ Range


10500 Humbolt Street
Los Alamitos, CA 90720 USA
T: 562.598.3015
F: 562.431.8507