  • An ultrasonic sensor should always be mounted perpendicular to the liquid surface
  • A VitonÆ mounting gasket should always be used when installing the sensor
  • Avoid fitting types or shapes with thick mounting structures located around the transducer threads greater than 3/8"
  • We recommend using Flowline plastic fittings, or equivalent, with thin wall mounting structures that isolate the transducer
Bulkhead Fittings
  • For 2" sensors, use Flowline's LM52-2890 low-profile 2" bulkhead fitting
  • For 1" sensors, add a LM52-1001 2" x 1" thread by thread reducer bushing
  • Avoid bulkhead fittings with internal threads or pipe stops forward of the installed transducer
Flanges
  • Always use a flange with the mounting threads above the plain of the flange
  • For 2" sensors, use Flowline's LM52-2890 2" flange
  • For 1" sensors, add a LM52-1001 2" x 1" thread by thread reducer bushing
  • If using a blind flange, tap a female thread 1" larger than the sensor's transducer size and use the appropriate reducer bushing
Riser
  • To avoid acoustic interference, follow the maximum riser height versus inner diameter
  • Riser height is defined as the distance from the installed face of the transducer to the opening in the tank
  • The inner diameter dictates the maximum riser height that the sensor can be installed on
Reducer Bushing
  • A reducer bushing will provide good isolation of the ultrasonic signal when mounted
  • Use a reducer bushing that isolates the sensor with a gap between the inner and outer threads
  • Use Flowline's 2" x 1" thread by thread LM52-1001 reducer bushing for all 1" sensors
Side-Mount Bracket
  • For installation on open tanks, use Flowline's LM50-1001 bracket (The LM52-1001 has a 2" female thread)
  • Flowline's LM52-1001-1 includes a 2" x 1" thread by thread reducer bushing for 1" sensors


Home | Search | Introduction | About Flowline | What's New | Solutions Wheel | Contact Flowline
Selection Guide | Application Guide | Browse the Products | Request Catalog | New Products
My Distributor | FAQs | Tech-Tips | Case Studies | Flowline News
Glossary | Success Stories | Technical | Chemical
Request Quote | Registration | White Papers

The Flowline Liquid Intelligence and Digital Infinity logo's are all trademarks and/or service marks of Flowline. No trademark or service mark license is granted in connection with the materials contained in the Flowline web site. This web site and all of the information it contains are provided as is without warranty of any kind, whether expressed or implied. All implied warranties, including, without limitation, implied warranties of merchantability, fitness for a particular purpose, and non-infringement, are hereby expressly disclaimed. No reproduction or republication without the prior written permission of Flowline. Specifications subject to change without notice.

©1999-2009 Flowline Liquid Intelligence
10500 Humbolt Street, Los Alamitos, CA 90720 USA
Phone: (562) 598-3015 • Fax: (562) 431-8507 • Email: levelsolutions@flowline.com